项目介绍

koide3/st_handeye_graph 是一个托管在 GitHub 上的开源项目,主要使用 C++ 编写,目前获得 81 个 Star、27 次 Fork。

仓库全名
koide3/st_handeye_graph
Star 数
81
Fork 数
27
未关闭 Issue
1

README 摘要

sthandeyegraph This package provides a general hand-eye calibration method which can be applied to pinhole and source-detector camera models. Description Unlike usual hand-eye calibration techniques, this method directly takes the images of the calibration pattern (like chessboard) and estimates the hand-eye transformation and the pattern pose such that the projection error of the pattern is minimized. Since it…

完整内容见 GitHub 原始 README 或本页 。

常见问题

st_handeye_graph 用什么语言开发?

主要使用 C++ 编写,目前有 81 个 Star。

如何获取 st_handeye_graph 的源码?

可以直接克隆仓库:git clone https://github.com/koide3/st_handeye_graph.git,默认分支为 master;安装与运行步骤见仓库 README。

st_handeye_graph 最近还在维护吗?

仓库最近一次更新为 2023年10月11日,当前有 1 个未关闭 Issue;Star 数为 81,可作为社区活跃度的参考。

关于

General hand-eye calibration based on reprojection error minimization and pose graph optimization

描述取自 GitHub 官方 API,中文内容由 GitRead 中文社区 编辑团队整理。

简要分析

热度分
137
价值分
56
活跃状态
活跃

README

st_handeye_graph

This package provides a general hand-eye calibration method which can be applied to pinhole and source-detector camera models.

Description

Unlike usual hand-eye calibration techniques, this method directly takes the images of the calibration pattern (like chessboard) and estimates the hand-eye transformation and the pattern pose such that the projection error of the pattern is minimized. Since it doesn’t rely on algorithms dedicated for pinhole cameras, such as PnP algorithms, it can be easily adapted to different camera model by changing only the projection model.

Dependencies

  • g2o
  • VISP
  • handeye_calib_camodocal (optional, for only evaluation)

Usage

Include “st_handeye/st_handeye.hpp” and call “st_handeye::spatial_calibration_graph()”. See “st_handeye.hpp” for the details.

Reproduce figures

git clone https://github.com/koide3/st_handeye_graph.git
git clone https://bitbucket.org/koide3/st_handeye_eval.git

mkdir st_handeye_graph/build
cd st_handeye_graph/build
cmake .. -DCMAKE_BUILD_TYPE=Release
make -j4

cd ../scripts
# run simulations and plot figures
./run_simulation.sh

# run calibration on real data and perform 3d reconstruction
./run_calibration.sh

# see the reconstructed point cloud
pcl_viewer data/points_3d_graph.pcd

Paper

Kenji Koide and Emanuele Menegatti, General Hand-Eye Calibration based on Reprojection Error Minimization, IEEE Robotics and Automation Letters/ICRA2019 [link].

Contact

Kenji Koide, Intelligent Autonomous Systems Laboratory, University of Padova, Italy. [email protected]

评论

暂无评论