OpenFlow
OpenFlow is a ventilation system built around Itho Daalderop’s
DemandFlow/QualityFlow
ventilation system.
In a nutshell, the DF/QF system works as follows: each room has an exhaust duct
connected to a central box up in the attic (the “plenum”). A ventilation unit
exhausts air through these ducts into the plenum and to the outside of the
house. Fresh air is pumped into the house in the staircase at the highest point
(typically close to the ventilation system). Instead of one CO2 sensor for every
room, the system uses a centralised CO2 sensor that sits in the plenum. To
determine which rooms need ventilating, the system continuously samples the CO2
levels, adjusting ventilation accordingly.
While this setup sounds interesting on paper, in practise it leaves a lot to be
desired. Most notably, the use of a single centralised CO2 sensor results in
skewed CO2 levels, which in turn results in the system ventilating the wrong
rooms or not ventilating them on time. In particular I found that if CO2 levels
rise in one room, the system has a tendency to think the levels are also
increasing in other rooms, even if those rooms haven’t been used for hours. As
the ventilation speed is based on the CO2 levels, this also leads to higher
exhaust speeds than should be necessary, and thus more noise.
Enter “OpenFlow”: a program written in Inko that takes
over control of the DF/QF system in an attempt to work around these issues.
Instead of using a single CO2 sensor, it uses MoreSense CO2
sensors for each room, and
Philips Hue motion
sensors for
bathrooms and toilets. OpenFlow also takes care to ventilate at lower speeds
whenever possible, reducing the amount of noise produced.
Requirements
If your Itho WiFi add-on has a CC1101 module attached, you can also use the
official Itho Daalderop RF remotes to control ventilation in rooms. This
requires that you set it up per the add-on’s documentation, then add it to your
config.json; see config.example.json for an example.
Installation
Assuming the WiFi module is set up, you’ll need to determine what the setting
indexes are to control the exhaust valves of the rooms you want to ventilate. To
obtain these indexes, go to the “Itho settings” page of the WiFi module and
click “Retrieve settings”. The settings you need will be called something along
the lines of “Flap position XXX with manual control” or “Damper position of XXX
with manual control”. The indexes are in the “Index” column.
Next you’ll need to find the settings indexes that enable the manual control
setting (most likely called “manual control”) and the exhaust fan speed
(“Ventilation requirement for exhaust air fan in manual mode (%)” or something
along those lines).
Third, you’ll need to determine the IP addresses of the WiFi module and the
Philips Hue bridge. OpenFlow doesn’t have support for service discovery of any
kind, nor can it resolve host names, so make sure to assign these devices a
static IP address. For the Hue bridge you’ll also need a user/API token. You can
find more information on how to do this on this
page.
With all the information gathered, copy config.example.json to
/etc/openflow.json and adjust it accordingly.
You can then build and run OpenFlow as follows:
inko build --release && ./build/release/openflow
You can also use the container built from main:
docker pull ghcr.io/yorickpeterse/openflow:main
docker run yorickpeterse/openflow:main openflow --help
For more information on how to use the executable, run openflow --help.