MIT License

项目介绍

downl2160/pscad-fault-analysis 是一个托管在 GitHub 上的开源项目,采用 MIT License 许可证,目前获得 6 个 Star、1 次 Fork。

仓库全名
downl2160/pscad-fault-analysis
开源许可证
MIT License
Star 数
6
Fork 数
1

README 摘要

PSCAD Fault Analysis Simulation of a single-phase line-to-ground fault scenario with overcurrent relay protection (IEEE 50) in PSCAD Free Edition v5. This project replicates a simple protection system and highlights both functionality and limitations faced while using PSCAD Free for educational/proof-of-concept purposes. ⚙️ Overview This project models: A single-phase power system with a 230 V, 50 Hz AC source A…

完整内容见 GitHub 原始 README 或本页 。

常见问题

pscad-fault-analysis 可以免费商用吗?

仓库采用 MIT License 许可证,可免费使用与修改,商业使用请遵守许可证条款(例如保留版权声明与许可声明)。

如何获取 pscad-fault-analysis 的源码?

可以直接克隆仓库:git clone https://github.com/downl2160/pscad-fault-analysis.git,默认分支为 main;安装与运行步骤见仓库 README。

pscad-fault-analysis 最近还在维护吗?

仓库最近一次更新为 2025年6月27日,当前没有未关闭的 Issue;Star 数为 6,可作为社区活跃度的参考。

关于

A single-phase line-to-ground fault simulation with overcurrent relay logic (IEEE 50) and breaker response modeled in PSCAD (2025)

描述取自 GitHub 官方 API,中文内容由 GitRead 中文社区 编辑团队整理。

贡献者

README

PSCAD Fault Analysis

Simulation of a single-phase line-to-ground fault scenario with overcurrent relay protection (IEEE 50) in PSCAD Free Edition v5. This project replicates a simple protection system and highlights both functionality and limitations faced while using PSCAD Free for educational/proof-of-concept purposes.


⚙️ Overview

This project models:

  • A single-phase power system with a 230 V, 50 Hz AC source
  • A line simulated using lumped R, L, and split capacitors (manual Pi-section)
  • An overcurrent relay (type 50) with a pickup of 15 A and delay of 0.05 s
  • A transistor used as a logic-controlled breaker (due to Free Edition limitations)
  • A load (5.3 Ω) connected beyond the fault point
  • A fixed line-to-ground fault, hard-connected without switching

📂 File Structure

pscad-fault-analysis/
├── README.md                  # This file
├── waveforms.csv              # Simulated or placeholder waveform data
├── project/
│   └── project_report.pdf     # Detailed simulation summary & limitations

⚡ Simulation Summary

  • Fault is active from t = 0 s (uncontrollable in Free Edition)
  • Relay detects overcurrent (>15 A)
  • After a delay of 0.05 s, the relay sends a signal to the transistor
  • Transistor opens the circuit, isolating the load

🔍 PSCAD Free Edition Limitations

This project was built under significant limitations of PSCAD Free v5:

Feature Status in Free Version
Graph plotting ❌ Not available
Step/Logic blocks ❌ Not available
Logic-controlled breakers ❌ Not available
Fault control timing ❌ Not possible
Waveform export (CSV) ✅ Available
Relay blocks (IEEE 50) ✅ Available

As a workaround:

  • The fault is always on (connected directly to ground)
  • A Constant block was temporarily used to simulate logic, but ultimately removed
  • A Transistor was used in place of a logic-controlled breaker

Despite these constraints, core protection logic is successfully demonstrated.


📈 Waveforms

See waveforms.csv for exported data:

  • Ia_1: Line current
  • Relay_output: Relay trip status
  • Switch_status: Breaker control status

These can be plotted in Python, Excel, or MATLAB.


📌 How to Run (Optional)

If re-using the simulation:

  1. Open project in PSCAD Free Edition v5
  2. Compile (Build)
  3. Run (Play button)
  4. Export data manually from Output Channels

📄 License

MIT License — for academic use.


📌 Author Notes

This simulation was completed under time constraints.

评论

暂无评论