TIA Portal MCP Server (V20 + V21 · S7DCL · CLI · read-only online monitoring · one-click config · Doctor)
Current version: see the Release badge below and CHANGELOG.md (this README no longer hardcodes a version).
English · 中文
v2.0 — the same exe is also a declarative CLI (tia). Any AI emits a
YAML/JSON spec, any engineer runs one command (tia gen spec.yaml) — no MCP
client required. Verbs: gen / patch / compile / describe / export /
import / prewarm / schema / version. Exit code 0/1/2. See
docs/CLI_quickstart.md. The MCP server behaviour is unchanged.

Free & open (MIT). The server runs with no license key — there is no
license-enforcement code at all.
🖥️ Don’t want to wire up an MCP client yourself? Try TIA 助手 (TIA Assist) —
the desktop edition built on this engine: unzip and run, built-in AI assistant, and every write to your
project waits for your approval first.
👉 aeenhance.com · 1-minute demo · Trial: [email protected] · Comparison ↓

Drive Siemens TIA Portal V20 or V21 from any MCP client (stdio or HTTP):
create projects, add hardware, generate PLC objects (Tag / UDT / DB / SCL / LAD),
build WinCC Unified screens and events, compile-and-diagnose, and save —
all through natural-language tool calls. The bundle ships prebuilt runtimes,
a Skill spec, a static tool list, a capability matrix, PLC/HMI templates,
one-shot project blueprints, and a manual. No separate source clone required
to run.
Works with any MCP-capable client — Cursor, VS Code, Claude Desktop, or your
own HTTP client — using the same TiaMcpServer.exe.
🆕 v2.5.0 — put a TIA Portal project under Git (Version Control Interface)
TIA Portal projects are binary, so Git cannot diff them — which is why “version
control” in this field has long meant a pile of dated Save As folders.
The V21 Version Control Interface maps a project onto an ordinary folder,
one text file per block, so it can be diffed, committed and reviewed.
This release wraps the whole round-trip into a few commands — you never have to
click anything inside the TIA Portal UI.
One sentence to your AI client is enough:
Put the current project under Git, use D:\repos\my-plc as the workspace
It creates the workspace → maps the whole project automatically (hundreds of
blocks in one command, no manual ticking) → exports the text, and you git commit.
Later, to see what changed:
GetVersionControlStatus(changedOnly=true)
→ A3_4_Hoist | Unequal ← per block, not per file
- Covered: FC / FB / OB / DB, PLC tag tables, UDTs — the whole software side.
Hardware configuration and know-how-protected blocks are not covered by the
VCI; the tool reports them explicitly instead of skipping them silently.
- A block must compile before it can be exported (a TIA limitation); change
detection is unaffected and works even on unsaved edits.
- Companion
tools/vci-watch/: after each successful compile it auto-exports,
writes the CHANGELOG and runs git commit — the engineer does nothing.
📖 Full usage and the three behaviours you must know →
docs/version-control-git.md
⚡ Fastest start (3 steps, no coding — CLI path)
First time? No MCP client, no code. Once TIA is installed, these 3 steps
generate your first project in minutes.
(Wiring an AI client like Cursor / Claude Desktop over MCP instead? See
Quick Start below.)
- Prepare: install TIA Portal V20 or V21 + .NET Framework 4.8; add your
Windows user to the local
Siemens TIA Openness group and log off/on once
(the group is not effective until re-login — the single most common blocker).
Use the exe matching your installed version — the bundle root ships
tia.cmd (V21) / tia-v20.cmd (V20); all other paths are auto-resolved.
- Health-check first: run
tia.cmd doctor (V20: tia-v20.cmd doctor) once after
install — it checks TIA install / exe-version match / Openness group / host
registration and prints the exact fix per problem (--fix auto-adds the group).
- Prewarm (optional, recommended): double-click
scripts\预热.bat and leave the
window open. It keeps one headless TIA resident so every later command connects in
~1s (without it, each run cold-starts ~3 min). Press Ctrl+C to close.
- Generate a project: drag a ready-made template
templates\project-blueprints\scaffold_spec_motor.json (or
scaffold_spec_start_stop.json) onto scripts\生成工程.bat — it creates the
project → adds PLC/HMI → builds blocks → compiles → saves in one shot. Exit code
0 means success.
- To customize: have any AI emit a spec per
docs/AI_spec_prompt.md
(YAML or JSON), then drag it onto 生成工程.bat.
- CLI equivalent: add the bundle root to PATH, then
tia gen <spec> (start with
--dry-run for an offline check).
TIA 助手 (TIA Assist) — the desktop edition

This repository is the engine: you bring your own AI client (Cursor, Claude, VS Code…) and mount it.
If you’d rather open an app and start working — or hand it to colleagues and commissioning engineers
who have never heard of MCP — the author also ships TIA 助手 (TIA Assist):
the same engine inside a Windows desktop app, with the AI assistant, online monitoring and trend
recording built into the UI. (The UI and website are currently Chinese-only.)

↑ Real screen capture (demo project): asked to write a duty/standby rotation FB for two pumps, it hit
4 compile warnings on the first build and fixed them itself down to 0 errors / 0 warnings — pausing for a
human “Yes” before every write. Watch the full recording →
|
Open-source MCP (this repo) |
TIA 助手 (desktop edition) |
| Form |
MCP server + tia CLI, driven by your own AI client |
Windows desktop app, no install — unzip and run; V20 / V21 engines bundled and picked automatically |
| AI |
Bring your own (Cursor / Claude Desktop / VS Code …) |
Built-in AI assistant; DeepSeek, Qwen, Kimi, Zhipu or any OpenAI-compatible API — or a local Ollama model, fully offline, project data never leaves the plant |
| Write safety |
Up to your client |
Every write waits for your approval; irreversible operations (e.g. deleting blocks) are confirmed separately; hash-chained audit log |
| Online values |
Read-only (S7 absolute addresses / OPC UA) |
No TIA Portal needed — symbolic read/write over S7CommPlus; writes off by default, forced read-back when enabled |
| Trend recording |
— |
Record, overlay/split, export and replay CSV |
| Environment check |
tia.cmd doctor (CLI) |
Graphical per-item check of runtimes / Openness allow-list / user group with the fix for each, one-click diagnostic bundle |
| License |
MIT, free |
Commercial — free trial available |
Try it: email [email protected] with your TIA Portal version (V20 / V21) and what you want to
try → get the trial package, run it, send back the machine code and receive a license key.
The safest first run: let it explain your own project read-only and check whether it got it right.
More: AI assistant · Online debugging · Safety boundaries · Manual · Get started
Both run the same engine: bugs fixed here are fixed there too, and issues reported here help both.
Highlights
- Stability-first public generation (v0.0.39).
PlcBuildAndImport now returns
CapabilityDecision, CapabilityWarnings, and RecommendedNextActions;
ApplyUnifiedHmiScreenDesignJson(strict=true) fails when any HMI property write
fails; EnsureUnifiedHmiTag(requireVerifiedBinding=true) requires readback as
SymbolicVerified or AbsoluteVerified.
- Dual-version support (V20 + V21). Two separate executables, not
interchangeable: V21 binds the split DLLs (
Siemens.Engineering.Base/Step7/…),
V20 binds the monolithic Siemens.Engineering.dll.
- V21 →
tools/tiaportal-mcp/src/TiaMcpServer/bin/Release/net48/TiaMcpServer.exe
- V20 →
tools/tiaportal-mcp/src/TiaMcpServer/bin-v20/Release/net48/TiaMcpServer.exe
- Version-safe imports. Generated Openness XML is normalized to the connected
portal version on import, so a V20 portal no longer rejects blocks with
“engineering version ‘V21’ is not supported”.
- S7DCL textual format.
ExportAsDocuments / ExportBlocksAsDocuments /
ImportFromDocuments / ImportBlocksFromDocuments read/write the diff-friendly
SIMATIC SD text format (.s7dcl + .s7res) on V20+ and are flagged PREFERRED on
V21+. The SimaticML XML chain remains for backward compatibility.
- 235 tools across project, hardware, PLC, HMI, and online operations,
layered
[L0]/[L1]/[L2] so a normal session only needs L0 + L1.
Requirements
- Windows + .NET Framework 4.8
- TIA Portal V20 or V21 installed
- Current user added to the
Siemens TIA Openness local group (re-login after)
Quick Start
-
Locate the portal install root (one of):
- pass
--tia-portal-location "D:\app\TIA20\Portal V20" when launching (recommended for non-default installs);
- set the
TiaPortalLocation user environment variable;
- let it auto-read
HKLM\SOFTWARE\Siemens\Automation\_InstalledSW\TIAP{20|21}\TIA_Opns\Path.
With multiple versions installed, pass --tia-major-version 20 (or 21) explicitly.
-
Mount the MCP — one command, fully automatic.
Double-click 配置MCP.bat in the bundle root (V20: 配置MCP-v20.bat), or run tia.cmd config.
Engine exe locations by distribution: Release zip →
tools\tiaportal-mcp\src\TiaMcpServer\bin\Release\net48\ (V21) /
...\bin-v20\Release\net48\ (V20); git clone → runtime\v21\
(V20 runtime is not shipped in git — download the Release zip).
All launcher scripts resolve both layouts automatically.
It self-discovers everything: its own absolute path, the installed TIA Portal
(registry) and version, and the version-matching exe (V20/V21 picked for you) —
then writes the tia-portal entry into every AI host detected on this machine:
Claude Desktop / Claude Code / Cursor / VS Code (existing config backed up
as .bak, other servers preserved). Restart the AI client to load it.
Options: config --host vscode (or claude|claude-code|cursor), config --print
to copy a snippet manually. The server lists 65 core tools of 235 by default
(about 57 KB instead of 196 KB of tool schema per turn) so weaker models are not drowned
and VS Code/Copilot’s 128-tool cap and Windsurf’s 100 never trip. Nothing is lost: the
model reaches every other tool on demand with FindTools("plain words") +
CallTool(name, argumentsJson), and the handshake instructions tell it so. Pass
config --full to list the whole tool surface instead.
If anything fails to connect, run tia.cmd doctor (v2.2.8): a one-shot environment
check (TIA install, exe/version match, Openness group, host registration) with the
exact fix per problem; --fix auto-adds the Openness group. Since v2.2.7 the exe also self-routes: if it was
built for a different TIA major version than the machine has, it transparently
re-execs the matching sibling exe — grabbing the “wrong” exe no longer crashes.
Manual fallback: copy the snippet from cursor-mcp.example.json, replace
REPLACE_ME with this bundle’s root, pick the exe path by TIA version; for
non-default installs add "--tia-portal-location","<root>","--tia-major-version","<20|21>" to args.
-
First call sequence: Bootstrap → Connect → OpenProject (or
CreateProject) → GetProjectTree, then read the real PLC_* / HMI_RT_*
paths from the tree before continuing.
Offline validation (no TIA needed)
powershell -NoProfile -ExecutionPolicy Bypass -File .\scripts\Validate-Bundle.ps1
Checks runtime presence, blueprint file completeness, tool-count consistency, and
that PLC/HMI JSON parse. Add -Strict for tighter manifest/matrix comparison.
Build from source
The full source lives under tools/tiaportal-mcp/src/TiaMcpServer (51 .cs).
# V21 (split DLLs)
dotnet build tools/tiaportal-mcp/src/TiaMcpServer/TiaMcpServer.csproj -c Release
# V20 (monolithic DLL) — clean intermediates first if you just built the other target
dotnet build tools/tiaportal-mcp/src/TiaMcpServer/TiaMcpServer.V20.csproj -c Release
Capabilities & boundaries
Can do: projects & hardware, PROFINET, declarative PLC import, LAD XML import,
WinCC Unified connections / tags (absolute addressing) / screens / button
Down·Up / dynamization, compile-and-diagnose, save.
Not bundled: Siemens install media, field projects, business-specific
technology. reference/ is style/instruction reference only. See notBundled in
manifest/package-manifest.json. For what Openness cannot do, see
手册/openness-limitations.md.
Read-only mode: start the server with --read-only (or TIA_MCP_READ_ONLY=1) and every call that could
change the project, the CPU or the open project is refused before it runs — listed tools, CallTool and the
HTTP bridge alike. Reads, exports (written to — and overwriting — the path you give, never the project) and
connect / open / close stay available; an older project is not upgraded on open, and an export blocked by an
online PLC is not taken offline for you. The flag covers the MCP server only (CLI verbs refuse to run with it).
The lite / full profile only decides which tools are listed; it is not a write protection.
Version branches & contributing
master is always the stable line for TIA Portal V20 / V21; its default
behaviour never changes to accommodate older releases. Earlier TIA Portal /
Openness versions live on their own branches, and contributions there are welcome:
| Branch |
Target version |
Maintenance |
master |
TIA Portal V20 / V21 |
Official main line (day-to-day work lands here) |
v21 |
TIA Portal V21 / Openness V21 |
Official; forked from master, V21-only adaptations |
v20 |
TIA Portal V20 / Openness V20 |
Official; forked from master, V20-only adaptations |
v19 |
TIA Portal V19 / Openness V19 |
Community |
v18 |
TIA Portal V18 / Openness V18 |
Community |
v17 |
TIA Portal V17 / Openness V17 |
Community |
v16 |
TIA Portal V16 / Openness V16 |
Community |
How to contribute
- Send a fix or adaptation for an older release to its own branch (a V17 change
goes to
v17), not to master.
v21 / v20 are official lines: anything that applies to both versions still
goes to master. Only use a version branch when a fix would change the other
version’s behaviour or depends on an API that exists in one version only — that
way shared code stays in one place.
- Older Openness APIs and block XML differ substantially, so branching lets each
version be validated independently without destabilising main-line users.
- If a fix turns out to be general and stable, a small follow-up PR back to
master is very welcome.
- Please do not commit: TIA project files (
.apXX), bin / obj, logs,
screenshots, backups, machine-specific absolute paths, or scratch test projects.
Want to adopt one of the version branches? Just say so in an Issue.
See CONTRIBUTING.md for the full workflow, and
SECURITY.md for reporting vulnerabilities.
Documentation map
| Path |
What |
tools/tiaportal-mcp/skill/SKILL.md |
Primary spec: tool layers, parameter traps, Unified HMI schema, LAD/SCL boundaries |
manifest/tools-list.json |
Static tool names/layers (runtime authority is tools/list after connect) |
docs/tool-capability-matrix.md |
Capability matrix |
docs/full-project-generation-runbook.md |
End-to-end project generation |
docs/scl-instruction-library.md / docs/lad-instruction-library.md |
SCL / LAD instruction libraries |
docs/hmi-connection-driver-matrix.md |
Communication-driver selection by CPU family |
手册/quickstart.md |
English quick start |
手册/TIA_NL_INTENT_RECIPES.md |
Natural-language → tool-sequence recipes |
Standard loop (abbreviated)
Bootstrap → Connect → CreateProject → AddDeviceWithFallback → AddHardwareCatalogDeviceWithProbe
→ ConnectDeviceNodesToProfinetSubnet → GetProjectTree → ValidateAutomationContext
→ PlcBuildAndImport(dryRun=true per item) → PlcBuildAndImport(dryRun=false in import order)
→ CompileAndDiagnosePlc → EnsureUnifiedHmiConnection → EnsureUnifiedHmiTagTable → EnsureUnifiedHmiTag
→ EnsureUnifiedHmiScreen → ApplyUnifiedHmiScreenDesignJson → BindUnifiedHmiTagDynamization
→ EnsureUnifiedHmiButtonAction → SaveProject → Disconnect
- Bugs / feature requests: please open an Issue so others hitting the same problem can find it.
- TIA 助手 trial, custom development, partnerships: [email protected]
- Desktop edition: aeenhance.com
Siemens, TIA Portal, SIMATIC, STEP 7 and WinCC are trademarks of Siemens AG. This project and TIA 助手 are independently developed third-party tools with no affiliation with, agency for, or authorization from Siemens AG.
评论