Table CWC made for WinCC Unified
1. CONTENT
HTML table
2. INTERFACE
- columns : Array of element for the columns title
columns: ["Parameter", "Read", "Value"]
- columnsEdit : Array of bool Flag to enable or diable (False / True) the text input area on a colum
columnsEdit: [false, false, true]
- columnsShow : Array of bool Flag to hide or dhow (False / True) a colum
columnsShow: [true, true, true]
rows: [["param01", "read1", "value1"], ["param02", "read2", "value2"], ["param03", "read3", "value3"]],
3. EVENTS
- ev_selectRow : This event is triggerd every time an user select or deselect a row, as a result if a row is selected in the “rowId” object is returned the content of the row with this structure:
- rowId = Row first column value
- rowVals = Array of values of all columns in the row
- The column value is returned also if that colum is not visible
// Example
{"rowId":"param01","rowVals":["param01","read1","value1"]}
- ev_updateRows : This event is triggerd every time an user update a row value by the text input area, as a result in the “rows” object is returned the updated content of the all the rows
// Example
[["param01", "read1", "value1"], ["param02", "read2", "value2"], ["param03", "read3", "value3"]]
- ev_updateRow : This event is triggerd every time an user update a row value by the text input area, as a result in the “rows” object is returned the updated content of the all the updated row
// Example
["param01", "read1", "value1"]
4. USAGE
-
OFFLINE MODE
- You can test the behavior of the table with custom data by setting “production” to false
- Now you can change all the data from “WebCC.Properties”
var production = false;
WebCC.Properties = {
select: true,
searching: false,
columns: ["Parameter", "Read", "Value"],
columnsEdit: [false, false, true],
columnsShow: [true, true, true],
rows: [["param01", "read1", "value1"],
["param02", "read2", "value2"],
["param03", "read3", "value3"]
],
pageLength: 18
};
-
ONLINE MODE (WinCC Unfied)
var production = true;
- To import the custom web control the hierarchy of folders and files must be compressed in ZIP format.
- The name of the ZIP must be the GUID used the “manifest.json” file surrounded by curly brackets
type": "guid://2823CFDE-FEE3-4B14-A792-96E2201EEAB8",
-
{2823CFDE-FEE3-4B14-A792-96E2201EEAB8}.zip
-
If you want this custom web control available for all your project, copy this file in the folder :
- C:\Program Files\Siemens\Automation\Portal V17\Data\Hmi\CustomControls
- replace “Porla V17” with your Tia version.
-
If you want to use this custom web control only in one project copy this file in the folder :
- \path_to_tia_project\UserFiles
-
Refresh “My controls” to update the files in TIA Portal
-
Now you can place the custom web control in the Screen.